All-in-one touchscreen displays with Android.

Knowledge and advice

Power consumption of trade fair stand displays: calculation by screen type

How many watts does a display on your trade fair stand use? Calculate it per screen type, plan your group correctly and comply with NEN 1010 — including a wattage table and circuit advice.

Installer checks power distribution at a trade fair stand with several commercial displays active during a trade fair

Power consumption of trade fair stand displays: calculation by screen type

A display on a trade fair stand consumes between 80 and 300 watts, depending on screen size, brightness level and screen type. A 43–49 inch commercial display draws an average of 100–150 W; a touchscreen kiosk with integrated computer is usually in the same range. If you add up several screens on one circuit, the total determines whether you need to request one or two power circuits — and whether you need to inform the trade fair organiser in time.

Why power consumption at a trade fair is different from at home

At home, a screen is on for an average of 1,5 to 4 hours. At a trade fair, displays run for 8 to 10 hours per day, sometimes longer during build-up and breakdown. Commercial displays are designed for continuous use; a consumer TV is not, and it also has a lower brightness (±300 nits), which makes it unsuitable for a busy exhibition hall.

Brightness has a direct impact on power consumption. A screen at maximum brightness (500 cd/m²) uses up to 40% more energy than on standard settings (300 cd/m²). At a trade fair you increase the brightness because of ambient light — so always calculate with the maximum power from the datasheet, not the average.

Watt table by screen type

The table below gives realistic ranges for the most commonly used screen types on trade fair stands. Use the upper limit for your power calculation.

Screen type Size Typical consumption Note
Commercial LCD display (indoor) 32″ 60–90 W No media player needed with integrated Android
Commercial LCD display (indoor) 43–49″ 100–150 W Most used on exhibition stands
Commercial LCD display (indoor) 55–75″ 150–250 W Always check the datasheet
Touchscreen kiosk (43–49″) 43–49″ 110–160 W Including touch overlay and computer
Outdoor display (3.500 cd/m²) 49–55″ 200–350 W Higher brightness = significantly more wattage
Battery-powered display (sidewalk sign) 43″ 0 W mains power Internal battery, 14–18 hours runtime
LED video wall (indoor) per m² 150–300 W/m² Depending on pixel pitch and content

Source bandwidth ranges: technical datasheets and industry figures (odys.nl, leddisplayexpert.nl).

One citable fact: a 43–49 inch commercial display on a trade fair stand consumes 100–150 W at full brightness; four such screens on one 16A circuit (max. ~3.680 W) fit comfortably, but if you add a coffee machine or lighting, you quickly reach the limit.

How to calculate total consumption

The basic formula is simple:

Total power (W) = Σ (watts per device × quantity) Required amperage = Total power ÷ 230 V

Calculation example — stand of 12 m² with three screens:

  • 3 × 43" commercial display: 3 × 130 W = 390 W
  • 1 × touchscreen kiosk 21,5″: 1 × 80 W = 80 W
  • Lighting (LED spots): 4 × 20 W = 80 W
  • Laptop + charger: 1 × 65 W = 65 W
  • Total: 615 W → ±2,7 A

One standard 16A circuit (3.680 W) is more than sufficient here. If you add a coffee machine (1.200–1.500 W), the load rises to approx. 1.800–2.100 W — still on one circuit, but then you are at 50–57% of the maximum capacity. That is acceptable; the rule of thumb is: never plan for more than 80% of the circuit capacity.

Always request the power application from the trade fair organiser in good time. Venues such as Jaarbeurs Utrecht, RAI Amsterdam and Rotterdam Ahoy each have their own exhibitor instructions with specific rules on power consumption and safety — check those before ordering or hiring materials.

Circuit planning: one or two groups?

Start with one group if your total consumption stays below 2.400 W (80% of 16A × 230 V). Choose two groups once:

  • You combine more than four 43–49″ screens with other equipment.
  • You use an outdoor display or LED video wall (200–350 W per m²).
  • The trade fair organiser requires a separate group for AV equipment.

Always split displays and other equipment over separate circuits. A coffee machine that peaks at start-up can trip a breaker — precisely when your stand is drawing visitors.

A smart choice for stand holders without a power connection: the PixioDisplay A-board runs on an internal battery with 14–18 hours of operating time and needs no power point at all. The price is current price on request (1.500 nits) or current price on request (2.000 nits) — price list Q2 2026. You save the costs of an extra power request from the trade fair organiser and the associated cable ramps.

Safety rules NL and BE

In the Netherlands, proper earthing is legally required under the NEN 1010 standard. Periodic inspections fall under NEN 3140. For temporary installations at trade fairs, the same requirements apply: use an earthed extension lead, do not daisy-chain multiple power strips from a single socket, and ensure there is a residual current device (RCD) on the stand's distribution board.

In Belgium, similar requirements apply through the AREI (General Regulation on Electrical Installations). At Flanders Expo, Brussels Expo or other Belgian venues, always ask for the technical sheet — it specifies the maximum connection value per exhibitor.

Practical checklist for the installer:

  • Calculate total power before requesting electricity from the organiser.
  • Use cable with at least 2,5 mm² for groups up to 16A.
  • Ensure there is an RCD (residual-current device) on the stand distributor.
  • Label each group with the connected device.
  • Test before opening: switch everything on at the same time and check that the circuit breaker does not trip.

Battery-powered displays as an alternative for tight power situations

Not every trade fair stand has direct access to a power circuit. For small stands, island setups or hire locations where extra power is expensive, a battery-powered display offers a solution. The PixioDisplay Pavement Sign (43″, 1.500 nits) runs 14 to 18 hours on one battery charge — enough for a full trade fair day without any cable connection. That also makes it suitable for stands where the organiser limits the number of power circuits.

For larger installations with multiple screens, hiring is an option to spread the investment. Via /display-huren/ rent a 43″ touchscreen display from current price on request per day (for three days, price list Q2 2026). You then know exactly how much power the hired screen draws — no surprises when requesting electricity.

Conclusion: calculate first, order afterwards

The rule of thumb is clear: add up all the power ratings, convert to amps, and plan for a maximum of 80% of the circuit capacity. One 16A circuit is sufficient for three to four 43–49″ displays plus peripherals. If you add a video wall, outdoor display or lots of lighting, request a second circuit.

If you want the full approach for displays at trade fairs — from content strategy to commissioning — also read the articles Trade fair stand displays: installation and commissioning checklist and Digital signage at festivals and events: outdoor screens, power and safety. For an overview of all display options for trade fairs and events, see /toepassingen/beurs-en-evenementendisplays/.

Frequently asked questions

How many watts does a 55 inch display use on a trade fair stand?

A 55 inch commercial display consumes 150 to 250 watts at full brightness. Always calculate with the upper limit from the datasheet, because at a trade fair you set the brightness higher than in an office environment. Include the media player or integrated computer in your calculation — for displays with a built-in Android computer, that is already included.

How many screens fit on one 16A circuit?

On a 16A group (230V), you have a maximum of 3.680 watts available. Use 80% as a safe upper limit: that is approx. 2.940 W. Four 43–49 inch displays of 130 W each plus some lighting will fit comfortably. If you add a coffee machine or other equipment, put it on a separate circuit.

Do I need to request separate power from the trade fair organiser for displays?

Yes. Almost all Dutch trade fair venues — Jaarbeurs, RAI, Ahoy, Brabanthallen — work with a power request form that you submit before a deadline. State the total power of all devices, including displays. Check the organiser's exhibitor instructions for the maximum connection value per stand.

Which safety standards apply to electrical installations at a trade fair stand in the Netherlands?

In the Netherlands, NEN 1010 (electrical installation work) and NEN 3140 (safe working on installations) apply. For temporary installations at trade fairs, this means: earthed connections, an earth leakage circuit breaker (RCD) on the stand distribution board, and cable of at least 2,5 mm² for circuits up to 16A. In Belgium, the requirements are similar via the AREI.

Can I use a display on a trade fair stand without a power connection?

Yes, with a battery-powered display such as the PixioDisplay A-board (43"). It runs for 14 to 18 hours on one battery charge and needs no power point at all. That is useful for island setups or when the organiser limits the number of power circuits. The price is €2.245 (1.500 nits) or €2.950 (2.000 nits) — price list Q2 2026.

Read also

The full price list

Request the price list brochure

The brochure brings all displays together, with the available purchase, rental and lease prices, versions and options. You will receive the price list by email.

Prefer a different step right away?

We will process your request and follow up by email. A Pixio specialist responds within one working day.