Knowledge and advice
IP54, IP65 and IP67: what do the codes mean for a display?
An IP code describes the tested protection of an enclosure against solid particles and water. Also check mounting, temperature and cleaning.

Read the two figures separately
IEC 60529 describes the degrees of protection of electrical enclosures. An IP code has two characteristic digits. The first relates to protection against solid objects and dust; the second to water. An X means that no degree of protection is specified for that part in the code. The code says something about the tested enclosure under the specified conditions. It does not replace an installation manual and is not a general statement that every part may remain outdoors permanently.
Dust protected is not the same as dustproof
With a first figure 5, dust may enter under the test conditions, as long as this has no harmful effect. The figure 6 stands for dust tightness under the relevant test. Ask whether the stated class applies to the complete display or, for example, only to the front. Cable entries, doors, connections and the way it is mounted can be important for protection. The final installation must continue to comply with the manufacturer's instructions.
Splashing water, jets and immersion
In the IP rating, 4 describes protection against splashing water, 5 against water jets and 6 against powerful water jets under defined test conditions. The figure 7 is about temporary immersion; that is a different test. An IP67 rating therefore does not automatically prove suitability for water jets or high-pressure cleaning. Separate test conditions apply for high pressure and temperature. Do not use a higher rating as carte blanche to treat a display with any cleaning method.
The codes combined
IP54 combines dust protection with splash-water protection. IP65 combines dust-tightness with protection against water jets. IP67 combines dust-tightness with protection against temporary immersion under the standard conditions. Always check the full marking and the instructions for the specific version.
What the IP code does not assess
The code does not indicate how bright the image is in the sun and gives no operating temperature, wind load or vandal resistance. Condensation, corrosion, UV exposure and the chosen maintenance products also require separate attention. A screen can have sufficient water protection and still be unsuitable for the temperature on a south-facing façade. Therefore ask for the full datasheet, mounting conditions and permitted environment. IP is one part of the product choice, together with the rest of the installation.
Agree cleaning and maintenance in advance
Describe how the location is cleaned and whether the display comes into contact with water, dust or cleaning agents. Use only the permitted cleaning method. Do not direct a pressure washer at connections or ventilation openings based on a general IP claim. After maintenance, check that doors and covers are properly closed. If there is damage or a missing seal, assess whether the device may still be used safely. Keep the product manual with the site's maintenance instructions.
This is how you compare quotes
For every quote, request the same details: the exact IP code, what it applies to, the mounting position, cable entry, temperature limits and cleaning instructions. There is no general minimum for every outdoor location. Have the manufacturer or supplier confirm that the complete setup is suitable for rain, dust and use at your site. View the outdoor displays and assess the product specifications separately from the requirements for installation behind glass.
Sources and further information
Frequently asked questions
Is IP67 automatically suitable for pressure washing?
No. IP67 describes dust tightness and temporary immersion under test conditions. Water jets and high pressure are separate tests.
Does the IP code prove that a display is fully suitable for outdoor use?
No. Also check temperature, sun, mounting, cable entry and cleaning requirements for the complete setup.